Residential Apartments & STRA properties Evacuation Diagrams

🏠👨👩👧👦 Residential Buildings Evacuation Diagram
For residential buildings, the Australian Standard AS 3745:2010 outlines the requirements for emergency planning and procedures. Key points include:
-
Mandatory for Workplaces: Evacuation diagrams are required in all workplaces under Australian Standard 3745.
-
Content Requirements: Diagrams must include elements such as designated exits, firefighting equipment, and the location of where the evacuation diagram is installed within the facility (i.e., the 'YOU ARE HERE' location).
-
Positioning: Evacuation diagrams should be positioned within a zone at a height not less than 1200 mm and not more than 1600 mm above the plane of the finished floor.
-
Orientation: Each evacuation diagram shall have the correct orientation with regard to the direction of egress and its location to the 'YOU ARE HERE' point.
🏡 Short-Term Rental Accommodation (STRA) – Evacuation Diagram Requirements
For STRA properties, such as Airbnbs and holiday rentals, specific fire safety standards apply, particularly in New South Wales (NSW):
NSW Fire Safety Standard for STRA (Effective from 1st November 2021)
-
Evacuation Diagram Placement: An evacuation diagram must be affixed:
-
Within the dwelling on or adjacent to the entrance door to the dwelling; and
-
Within each bedroom on or adjacent to the door to the room. Planning NSW
-
-
Diagram Specifications:
-
Be at least A4 in size;
-
Be located no less than 1200mm and not more than 1600mm above the finished floor level;
-
Be clear, legible, and durable;
-
Include the date of issue. Planning NSW
-
-
Additional Requirements:
-
Installation of a fire blanket in an accessible location in the kitchen;
-
Installation of a 2.5 kg ABE portable fire extinguisher in an accessible location in the kitchen;
-
Smoke alarms complying with AS 3786, powered from the mains electricity supply or by a non-removable battery with a minimum life expectancy of 10 years. Planning NSW
-
Other States and Territories
While NSW has specific regulations for STRA properties, other states and territories in Australia may have different requirements. It's essential to consult local regulations to ensure compliance.
✅ Key Takeaways
-
Residential Buildings: Evacuation diagrams are mandatory in workplaces under AS 3745-2010, with specific content and positioning requirements.
-
STRA Properties: In NSW, STRA properties must comply with the Fire Safety Standard, including specific evacuation diagram requirements and additional fire safety measures.
-
Compliance: Ensure that your property meets the relevant standards and regulations to guarantee safety and legal compliance.
📩 Let’s help you stay compliant and protect your community.
Get started by emailing us at info@evacuationdiagram.com.au