AS 3745:2010 Evacuation Diagram Design Specialists

A Specialist Brand of FirePlan Pvt. Ltd.
Evacuation Diagram Sizes, Printing & Installation in Australia
A Practical Guide to AS 3745:2010 Evacuation Diagram Requirements
Evacuation diagrams play an important role in helping building occupants and visitors identify emergency exits, evacuation routes, firefighting equipment and designated assembly areas.
​
In Australia, evacuation diagram design, size, positioning and display requirements are guided by AS 3745:2010 – Planning for Emergencies in Facilities, including its amendments.
​
Understanding the correct diagram size, printing options and installation requirements helps ensure emergency information is clearly presented, accessible and suitable for the building.
Evacuation Diagram Frame Sizes

A4: 210 x 297 mm
A3: 297x 420 mm
A2- 420 x 594 mm
A1-594 x 841 mm
1. Evacuation Diagram Sizes in Australia
Choosing the Right Size for Your Building or Industry
Australian Standard AS 3745:2010 specifies minimum evacuation diagram sizes based on the information included in the diagram, rather than solely on the building type.
The three commonly used sizes are A4, A3 and A2.
​
A4 Evacuation Diagrams — Minimum Size
Dimensions: 210 mm × 297 mm
A4 is the minimum permitted size for an evacuation diagram containing only the mandatory elements specified under AS 3745:2010.
The floor plan illustration must also meet the minimum pictorial representation size requirements of the Standard.
Typical Applications:
-
Small offices with simple layouts
-
Small retail premises
-
Hotel and motel guest rooms
-
Serviced accommodation
-
Small facilities with limited floor plan information
A4 should only be selected where the required information can be displayed clearly and no optional elements are included.
​
A3 Evacuation Diagrams — Recommended Size
Dimensions: 297 mm × 420 mm
A3 is our preferred and recommended size for most Australian commercial, residential common-area and industrial evacuation diagram applications.
Under AS 3745:2010, A3 is the minimum required size when optional information is included in addition to the mandatory elements.
The larger format provides additional space for floor plans, evacuation information, symbols, legends and emergency instructions.
​
Recommended Applications:
-
Commercial offices and corporate buildings
-
Schools and educational facilities
-
Childcare and early learning centres
-
Aged care facilities
-
Apartment buildings and common areas
-
Hotels and accommodation facilities
-
Restaurants and shopping premises
-
Warehouses and industrial workplaces
-
Medical centres and healthcare facilities
EDA Recommendation: We recommend A3 for most projects because it offers a practical balance between readability, presentation quality and available wall space.
​
A2 Evacuation Diagrams — Large and Complex Facilities
Dimensions: 420 mm × 594 mm
A2 or larger formats may be considered where building layouts or site information require additional display space.
Suitable Applications May Include:
​
-
Large hospitals and healthcare complexes
-
Shopping centres and retail complexes
-
Airports and transport facilities
-
Large industrial and manufacturing sites
-
Universities and educational campuses
-
Large warehouses and distribution centres
-
Complex multi-building facilities
For large or complicated buildings, dividing the floor plan into clearly identified sections may be more effective than simply increasing the diagram size.
​
The final diagram size should be selected according to the building layout, information requirements, readability and applicable Australian Standards.
​
Important: A4 and A3 have different minimum content and floor plan size requirements under Clause 3.5.7 of
AS 3745:2010. The building type alone does not determine the mandatory diagram size
Lamination & Framing of Evacuation Diagrams

2. Printing, Lamination & Framing of Evacuation Diagrams
Professional Printing and Display Options
Once an evacuation diagram has been prepared and approved, it should be printed clearly and displayed in a suitable, durable format.
​
High-quality printing and appropriate finishing help protect the diagram from physical damage, fading and everyday environmental conditions.
​
Full-Colour Printing
Evacuation diagrams should be printed in full colour to preserve the identification of emergency exits, evacuation routes, fire safety equipment and relevant safety symbols.
We recommend:
-
High-quality colour printing
-
Printing at the approved original document size
-
Clear and readable text and symbols
-
Suitable paper or printing material
-
Accurate reproduction of emergency symbol colours
-
Avoiding excessive scaling or cropping
​
Lamination
Lamination is a practical and economical finishing option, particularly for indoor areas.
It helps protect printed diagrams from moisture, dust, fingerprints and general wear.
Recommended Options:
-
Matte lamination to help reduce reflections and glare
-
Gloss lamination where lighting conditions allow
-
Durable laminated prints for offices, corridors, classrooms and other indoor locations
​
Aluminium Frames
Aluminium snap frames are a popular choice for professionally displaying evacuation diagrams.
They provide a neat appearance and allow diagrams to be replaced when building layouts or emergency information are updated.
Suitable Locations:
-
Office buildings
-
Commercial facilities
-
Hotels and accommodation
-
Schools and educational facilities
-
Apartment common areas
-
Reception areas and shared corridors
​
Acrylic and Other Display Options
Clear acrylic holders, rigid panels and other suitable mounting systems may also be used depending on the building environment.
For outdoor or exposed locations, weather-resistant printing materials and suitable protective finishes are recommended.
Important: AS 3745:2010 does not prescribe one universal printing, lamination or framing method. The chosen finish should maintain legibility, durability and safe installation.
​
EDA Digital Delivery Service
At Evacuation Diagram Australia, we specialise in professional evacuation diagram drafting and digital delivery.
​
Our completed drawings are supplied in print-ready PDF formats, including A3 and A4, with A2 formats available where required. JPEG files can also be provided.
​
Once your drawings are approved, you can arrange printing, lamination, framing and installation through your preferred local Australian service provider.
​
We Prepare the Drawings. You Arrange Local Printing and Installation.
Display of Evacuation Diagram
3. Process of Evacuation Diagram Installation
Where and How Should Evacuation Diagrams Be Installed?
Correct installation is just as important as professional diagram preparation.
Australian Standard AS 3745:2010 provides guidance on the positioning, location and orientation of evacuation diagrams to ensure occupants and visitors can access emergency information.
​
Step 1 — Confirm the Installation Locations
Evacuation diagrams must be displayed where building occupants and visitors can view them.
Depending on the building layout and emergency planning requirements, suitable locations may include:
-
Main building entrances and exits
-
Common corridors and circulation areas
-
Reception areas and lift lobbies
-
Locations near emergency exits and stairways
-
Shared areas within commercial and residential buildings
-
Staff areas and other regularly occupied spaces
-
Guest rooms or individual rooms where required by applicable regulations or the facility's emergency arrangements
​
The number and specific locations of evacuation diagrams should be determined by the facility's Emergency Planning Committee (EPC) or our evacuation diagram team.
​
Additional industry-specific or state and territory regulations may apply. For example, approved childcare services must display emergency and evacuation floor plans and instructions prominently near each exit.
​
Step 2 — Confirm the Installation Height
Recommended Positioning: 1,200 mm–1,600 mm Above Finished Floor Level (FFL)
Clause 3.5.3 of AS 3745:2010 provides positioning guidance using the lower or upper edge of the diagram.
The diagram should be positioned with either its bottom edge at least 1,200 mm above the finished floor or its top edge no higher than 1,600 mm above the floor.
Install diagrams where they can be viewed comfortably and without obstruction.
​
Step 3 — Check the Diagram Orientation
Each evacuation diagram must be correctly oriented according to its installation location and the direction of evacuation.
​
The “YOU ARE HERE” marker must accurately represent the actual position of the person viewing the diagram.
The floor plan should be rotated where necessary so that its orientation corresponds to the viewer's surroundings.
If an assembly area plan is included, it must follow the same orientation as the main floor plan.
​
A diagram prepared for one wall location should not automatically be installed at another location without checking its orientation and “YOU ARE HERE” position.
​
Step 4 — Securely Install the Diagram
Use a suitable mounting or framing method to keep the diagram securely in place and clearly visible.
Avoid locations where diagrams may be obscured by furniture, storage, doors, decorations or other obstructions.
Important Fire Door Safety Consideration:
Evacuation diagrams should not be attached to fire doors, smoke doors or other fire-resistant building elements unless the proposed installation has been appropriately assessed through testing or a formal opinion from a suitably qualified authority.
Drilling, adhesive materials, frames or other attachments may affect the fire-resistance performance of these elements.
​
Step 5 — Final Inspection and Ongoing Review
After installation, confirm that:
-
Each diagram is installed at its approved location.
-
The “YOU ARE HERE” marker matches the actual position.
-
The diagram orientation is correct.
-
Emergency exits, evacuation routes and assembly information are accurate.
-
All text, symbols and legends remain clearly visible.
-
The diagram is securely installed and unobstructed.
-
The displayed information reflects the facility's current emergency plan.
Evacuation diagrams should be reviewed and updated whenever changes affect the building layout, emergency exits, fire safety equipment, evacuation arrangements or other displayed information.
The validity period and applicable state or territory review requirements should also be followed.
​
Need Professional Evacuation Diagrams?
Evacuation Diagram Australia (EDA) provides specialist online drafting services for Australian businesses, fire protection companies and fire safety consultants.
​
With over 21 years of industry experience, we prepare professionally presented evacuation diagrams designed to meet AS 3745:2010 requirements, using verified information supplied by our clients.
​
100% Online Service | Professional PDF Drawings | Australia-Wide Delivery
​
Request a Quote | Become a Trade Partner
​
