Fire Alarm Zone Plans
Fire Alarm Zone Plan –
Mandatory for Buildings with Detection Systems
Buildings fitted with a Fire Detection and Alarm System must have an up-to-date Fire Alarm Zone Chart displayed clearly adjacent to the Fire Indicator Panel (FIP) and any repeater panels on the premises.
This is a mandatory requirement under Australian Standards, specifically outlined in AS 1670.1 and Building Fire Safety Regulations.
Purpose of a Fire Alarm Zone Chart
The Fire Alarm Zone Chart serves a critical safety function. It is designed to:
-
Help building occupants and fire wardens quickly identify the location of a fire alarm trigger
-
Assist emergency responders and the Fire Brigade in understanding the building layout before entering
-
Improve response time and coordination during an emergency
-
Minimise confusion by presenting a clear visual layout of all designated fire zones
How Fire Zones Work
When a fire detection system is installed, the building is divided into separate Fire Zones. These zones correspond to:
-
Smoke or heat detectors
-
Manual Call Points (MCPs) – red break-glass alarm boxes
-
Other automatic detection devices
When any of these devices are triggered, the associated zone is activated and shown on the Fire Indicator Panel (FIP).
What the Fire Alarm Zone Chart Includes
A compliant Fire Alarm Zone Chart must include:
-
A scaled or schematic floor plan of the building or affected area
-
Clearly marked fire zones (Zone 1, Zone 2, etc.)
-
The location of the Fire Indicator Panel marked with a "You Are Here" arrow
-
Orientation of the diagram to match the viewer's perspective (usually facing outward from the FIP)
-
Optional but useful:
-
Fire stairs, exits, hydrants, hose reels, and extinguishers
-
Room labels and key risk areas (e.g., switch rooms, plant rooms)
-
Compliance Checklist
✔️ Mounted next to the Fire Indicator Panel
✔️ Laminated or in a protective frame
✔️ Aligned with current zone configuration
✔️ Updated after any renovation or detector reconfiguration
✔️ Readable from 1–2 metres distance
✔️ Format and symbols per AS 1670.1 & AS 3745:2010
Would you like a Fire Alarm Zone Chart design sample, or would you like us to create one for your building based on your floor plan and zone list?
Let me know — we can prepare a fully compliant and professional version within 24–72 hours.
Fire Alarm Zone Plan – Australian Standard Overview
A Fire Alarm Zone Plan is a mandatory diagram installed next to the Fire Indicator Panel (FIP) in accordance with AS 1670.1 and local fire brigade requirements.
It shows:
✅ A simplified building layout.
✅ Clear division into fire alarm zones, matching the FIP.
✅ Correct orientation with a 'YOU ARE HERE' marker.
✅ Helps emergency responders quickly identify and locate the zone in alarm.
✅ Supports safe evacuation and detector testing as per AS 1851 routine service checks.
Zone plans must be:
Accurate and up to date.
Easy to read (simple line drawings, labels, no clutter).
Permanently fixed next to the FIP, Sub-FIP, or Mimic Panel.
High Rise Fire Alarm Zone Plans
In many high-rise buildings across Australia, multiple floors have identical or mirrored layouts. To maintain clarity and legibility in fire alarm zone plans, a "typical floor layout" method is commonly used.
What This Includes:
-
One ‘Typical Floor Plan’: A single detailed plan representing the common floor layout (e.g. Levels 5–15).
-
Elevation View or Floor Index: An adjacent elevation diagram or vertical zone key showing:
-
Each level.
-
The associated fire alarm zones per floor.
-
Clear mapping to the Fire Indicator Panel (FIP) zone configuration.
-
Benefits:
-
Maximises the size of the plan to clearly show circulation paths (e.g. corridors, stairs, exits).
-
Reduces clutter from repeating nearly identical plans.
-
Fully compliant with AS 1670.1 and fire brigade preferences.
-
Helps responders quickly interpret multi-level zone assignments in emergencies.